(device-polling)=

# Device polling

```{tags} audience:developers, lang:c++, lang:all
```

## Introduction

Each tango device server automatically has a separate polling thread pool. Polling a device means periodically executing
command or reading attributes on a device and storing the results, or the thrown exception, in a polling buffer.

The aim of polling is threefold:

- Speed-up response time for slow devices
- Get a first-level history of device command output or attribute value
- Be the data source for the Tango event system

Speeding-up response time is achieved because the `command_inout` or
`read_attribute` CORBA operation is able to get its data from the polling
buffer or from a real access to the device. For "slow" devices,
getting the data from the buffer is much faster than accessing the
device. Returning a first-level command output history (or attribute
value history) to a client is possible due to the polling buffer which
is managed as a circular buffer. The history is the contents of this
circular buffer. The polling is also the data source for the event
system because detecting an event means being able to regularly read the
data, store it and declaring that it is an event after some
comparison with older values.

There are currently two polling algorithms available, the current one and the old one. See the reference section on
[polling properties](#device-polling-properties) to get details on this.

## Configuring the polling system

### Configuring what has to be polled and how

It is possible to configure the polling in order to poll:

- Any command which does not need input parameter
- Any attribute

Configuring the polling is done by sending a command to the device server
administration device automatically implemented in every device server
process. Seven commands are dedicated to this feature.

These commands are:

**AddObjPolling**

: It adds a new object (command or attribute) to the list of object(s)
  to be polled. It is also with this command that the polling period
  is specified.

**RemObjPolling**

: To remove one object (command or attribute) from the polled
  object(s) list

**UpdObjPollingPeriod**

: Changes one object polling period

**StartPolling**

: Starts polling for the whole process

**StopPolling**

: Stops polling for the whole process

**PolledDevice**

: Allows a client to know which device are polled

**DevPollStatus**

: Allows a client to precisely knows the polling status for a device

All the necessary parameters for the polling configuration are stored in
the Tango database. Therefore, the polling configuration is not lost
after a device server process stop and restart (or after a device server
process crash).

It is also possible to automatically poll a command (or an attribute)
without sending command to the admin device. This
demands to add a method call in the device server source code while
creating the command or attribute. In this case, for every device
supporting this command or this attribute, polling configuration will be
automatically updated in the database and the polling will start
automatically at each device server process startup. It is possible to
stop this behavior on a device basis by sending a RemObjPolling command
to the admin device. The following piece of code
shows how the source code should be written.

```{code} cpp
:number-lines: 1

  void DevTestClass::command_factory()
  {
      ...
      command_list.push_back(new IOStartPoll("IOStartPoll",
                                              Tango::DEV_VOID,
                                              Tango::DEV_LONG,
                                              "Void",
                                              "Constant number"));
      command_list.back()->set_polling_period(400);
      ...
  }


  void DevTestClass::attribute_factory(vector<Tango::Attr *> &att_list)
  {
      ...
      att_list.push_back(new Tango::Attr("String_attr",
                                          Tango::DEV_STRING,
                                          Tango::READ));
      att_list.back()->set_polling_period(250);
      ...
  }
```

A polling period of 400 ms is set for the command called `IOStartPoll`
at line 9 with the `set_polling_period` method of the Command class.
Therefore, for a device of this class, the polling thread will start
polling its `IOStartPoll` command at process start-up except if a
RemObjPolling indicating this device and the `IOStartPoll` command has
already been received by the admin device. This
is exactly the same behavior for attribute. The polling period for
attribute called `String_attr` is defined at line 20.

Configuring the polling means defining the device attribute/command polling
period. The polling period has to be choosen with care. If reading an
attribute needs 200 ms, there is no point polling this attribute with a
period equal to or below 200 ms. You should also take into
account that some free time has to be foreseen for external requests
on the device. On average, for one attribute needing X ms as reading
time, define a polling period which is equal to 1.4 X (280 ms for our
example of one attribute needing 200 ms as reading time). In case the
polling tuning is given to external user, Tango provides a way to define
polling period minimun threshold. This is done using device properties.
These properties are named `min_poll_period`, `cmd_min_poll_period`
and `attr_min_poll_period`. The property `min_poll_period`
defines a minimum polling period in milliseconds for the device. The property
`cmd_min_poll_period` allows the definition of a minimun polling period
for a specific device command. The property `attr_min_poll_period`
allows the definition of a minimun polling period for one device
attribute. In case these properties are defined, it is not possible to
poll the device command/attribute with a polling period below those
defined by these properties. See [polling properties](#device-polling-properties)
to get a precise syntax description for these properties.

[Jive](inv:jive:std#index) also allows a graphical device
polling configuration.

### Configuring the polling threads pool

A Tango device server process may have
several polling threads managed as a pool. For instance, this could be
useful in case of devices within the same device server process but
accessing to different hardware channels when one of the channels is
not responding (Thus generating long timeout and de-synchronising the
polling thread). By default, the polling threads pool size is set to 1
and all the polled object(s) are managed by the same thread. The
configuration of the polling thread pool is done using two properties
associated to the admin device. These properties
are named:

- `polling_threads_pool_size` defining the maximun number of threads
  that you can have in the pool
- `polling_threads_pool_conf` defining which threads in the pool
  manages which device

The granularity of the polling threads pool tuning is the device. You
cannot ask the polling threads pool to have thread number 1 in charge of
attribute *att1* of device *dev1* and thread number 2 to be in charge of
*att2* of the same device *dev1*.

When you require a new object (command or attribute) to be polled, two
main cases may arise:

1. Some polled object(s) belonging to the device are already polled by
   one of the polling threads in the pool: There is no new thread
   created. The object is simply added to the list of objects to be
   polled for the existing thread

2. There is no thread already created for the device. We have two
   sub-cases:

   1. The number of polling threads is less than the
      `polling_threads_pool_size`: A new thread is created and started
      to poll the object (command or attribute)
   2. The number of polling threads is already equal to the
      `polling_threads_pool_size`: The software search for the thread
      with the smallest number of polled objects and add the new polled
      object to this thread

Each time the polling threads pool configuration is changed, it is
written in the database using the `polling_threads_pool_conf` property.
If the behaviour previously described does not fulfill your needs, it is
possible to update the polling_threads_pool_conf property in a
graphical way using [Astor](inv:astor:std#index)
or manually using [Jive](inv:jive:std#index). These
changes will be taken into account at the next device server process
start-up. At start-up, the polling threads pool will allways be
configured as required by the polling_threads_pool_conf property. The
syntax used for this property is described in the [polling properties](#device-polling-properties) reference part.

The following screenshot is the Astor tool window which allows polling threads pool management.

```{image} polling/ThreadsManagement.png
```

In this example, the polling threads pool size to set to 9 but only 4
polling threads are running. Thread 1 is in charge of all polled objects
related to device `pv/thread-pool/test-1` and `pv/thread-pool/test-2`.
Thread 2 is in charge of all polled objects related to device
`pv/thread-pool/test-3`. Thread 3 is in charge of all polled objects
related to device `pv/thread-pool/test-5` and finally, thread 4 is in
charge of all polled objects for devices `pv/thread-pool/test-4`,
`pv/thread-pool/test-6` and `pv/thread-pool/test-7`.

It’s also possible to define the polling threads pool size
programmatically in the main function of a device server process using
the `Util::set_polling_threads_pool_size()` method before the call
to the `Util::server_init()` method.

### Choosing polling algorithm

Starting with Tango 9, you can choose between two different polling
algorithm:

- The polling as it was in Tango since it has been introduced. This
  means:

  - For one device, always poll attribute one at a time even if the
    polling period is the same (use of read_attribute instead of
    read_attributes)
  - Do not allow the polling thread to be late: If it is the case
    (because at the end of polling object 1, the current time is
    greater than the polling date planned for object 2), discard
    polling object and inform event user by sending one event with
    error (Polling thread is late and discard....)

- New polling algorithm introduced in Tango 9 as the default one. This
  means:

  - For one device, poll all attributes with the same polling period
    using a single device call (read_attributes)
  - Allow the polling thread to be late but only if number of late
    objects decreases.

The advantages of new polling algorithm are

1. In case of several attributes polled on the same device at the same
   period a lower device occupation time by the polling thread (due to a
   single read_attributes() call instead of several single
   read_attribute() calls)
2. Less `Polling thread late` errors in the event system in case of
   device with non constant response time

The drawback is

1. The loss of attribute individual timing data reported in the polling
   thread status

It is still possible to return to pre-release 9 polling algorithm. To do
so, you can use the device server process administration device
`polling_before_9` property by setting it to true. It is also possible
to choose this pre-release 9 algorithm in device server process code in
the main function of the process using the `Util::set_polling_before_9()` method.

## Reading data from the polling buffer

For a polled command or a polled attribute, a client has three
possibilities to get command result or attribute value (or the thrown
exception) :

- From the device itself
- From the polling buffer
- From the polling buffer first and from the device if data in the
  polling buffer are invalid or if the polling is badly configured.

The choice is done during the command_inout CORBA operation by
positioning one of the operation parameter. When reading data from the
polling buffer, several error cases are possible:

- The data in the buffer is not valid any more. Every time data is
  requested from the polling buffer, a check is done between the client
  request date and the date when the data were stored in the buffer. An
  exception is thrown if the delta is greater than the polling period
  multiplied by a “too old” factor. This factor has a default value and
  can be set via the `poll_old_factor` device property, see also [polling properties](#device-polling-properties).
- The polling is correctly configured but there is no data yet in the
  polling buffer.

## Retrieving command/attribute result history

The polling thread stores the command result or attribute value in
circular buffers. It is possible to retrieve an history of the command
result (or attribute value) from these polling buffers. For commands, a
CORBA operation called `command_inout_history_2` allows this
retrieval. The client specifies the command name and the record number
to retrieve. For each record, the call returns the date when the
command was executed, the command result or the exception stack in case
of the command failed when it was executed by the polling thread. In
such a case, the exception stack is sent as a structure member and not
as an exception. The same thing is available for attribute. The CORBA
operation name is `read_attribute_history_2`. For these two calls,
there is no check done between the call date and the record date in
contrary of the call to retrieve the last command result (or attribute
value).

## Externally triggered polling

Sometimes, rather than polling a command or an attribute regulary with a
fixed period, it is more interesting to manually decide when the
polling must occur. The Tango polling system also supports this kind of
usage. This is called `externally triggered polling`. To define one
attribute (or command) as externally triggered, simply set its polling
period to 0. This can be done with the admin device [AddObjPolling](#addobjpolling-admin-comand) or
[UpdObjPollingPeriod](#updobjpollingperiod-admin-comand) commands. Once in this mode, the attribute (or command)
polling is triggered with the `trigger_cmd_polling`/`trigger_attr_polling` methods
of the Util class. The following piece of code shows how this method could be used for one externally triggered command.

```{code} cpp
:number-lines: 1

  .....

  std::string ext_polled_cmd{"MyCmd"};
  Tango::DeviceImpl *device = .....;

  auto *tg = Tango::Util::instance();

  tg->trigger_cmd_polling(device, ext_polled_cmd);

  .....
```

line 3 : The externally polled command name

line 4 : The device object

line 8 : Trigger polling of command MyCmd

## Filling polling buffer

Assume that some hardware to be interfaced already returned an array of value,
timestamp pairs. In order to be read with the `command_inout_history` or
`read_attribute_history` calls, this array has to be transferred in
the attribute or command polling buffer. This is possible only for
attribute or command configured in the externally triggered polling
mode. Once in externally triggered polling mode, the attribute (or
command) polling buffer is filled with the
`fill_cmd_polling_buffer`/`fill_attr_polling_buffer` methods of the Util class.
For commands, the user uses a template class called `TimedCmdData` for each element of
the command history. Each element is stored in a stack in one instance
of a template class called `CmdHistoryStack`. This object is one of the
argument of the `fill_cmd_polling_buffer` method. See [polling properties](#device-polling-properties)
 how to learn the polling buffer depth can be defined. The same way is used for attributes with the `TimedAttrData` and
`AttrHistoryStack` template classes. The following piece of code fills the
polling buffer for a command called `MyCmd` which is already in externally
triggered mode. It returns a `DevVarLongArray` data type with three
elements.

```{code} cpp
:number-lines: 1

  ....

  Tango::DevVarLongArray dvla_array[4];

  for(int i = 0; i < 4; i++)
  {
      dvla_array[i].length(3);
      dvla_array[i][0] = 10 + i;
      dvla_array[i][1] = 11 + i;
      dvla_array[i][2] = 12 + i;
  }

  Tango::CmdHistoryStack<DevVarLongArray> chs;
  chs.length(4);

  for (int k = 0; k < 4; k++)
  {
      auto when = time(NULL);

      Tango::TimedCmdData<DevVarLongArray> tcd(&dvla_array[k], when);
      chs.push(tcd);
  }

  auto *tg = Tango::Util::instance();
  string cmd_name{"MyCmd"};
  DeviceImpl *dev = ....;

  tg->fill_cmd_polling_buffer(dev,cmd_name,chs);

  .....
```

Line 3-11 : Simulate data coming from hardware

Line 13-14 : Create one instance of the CmdHistoryStack class and
reserve space for one history of 4 elements

Line 16-17 : A loop on each history element

Line 18 : Get date (hardware simulation)

Line 20 : Create one instance of the TimedCmdData class with data and
date

Line 21 : Store this command history element in the history stack. The
element order will be the insertion order whatever the element date is.

Line 28 : Fill command polling buffer

After one execution of this code, a `command_inout_history` call will
return one history with 4 elements. The first array element of the
oldest history record will have the value 10. The first array element of
the newest history record will have the value 13. A `command_inout`
call with the data source parameter set to CACHE will return the newest
history record (ie an array with values 13,14 and 15). A
`command_inout` call with the data source parameter set to DEVICE will
return what the command method code returns. If you execute this code a
second time, a `command_inout_history` call will return an history of
8 elements.

The next example fills the polling buffer for an attribute called MyAttr
which is already in externally triggered mode. It is a scalar attribute
of the `DevString` data type.

```{code} cpp
:number-lines: 1

  ....

  Tango::AttrHistoryStack<DevString> ahs;
  ahs.length(3);

  for (int k = 0;k < 3;k++)
  {
      auto when = time(NULL);

      auto *ptr = Tango::string_dup("Attr history data");

      Tango::TimedAttrData<DevString> tad(ptr, Tango::ATTR_VALID, true, when);
      ahs.push(tad);
  }

  auto *tg = Tango::Util::instance();
  std::string attr_name{"MyAttr"};
  Tango::DeviceImpl *dev = ....;

  tg->fill_attr_polling_buffer(dev, attr_name, ahs);

  .....
```

Line 3-4 : Create one instance of the AttrHistoryStack class and reserve
space for an history with 3 elements

Line 6-7 : A loop on each history element

Line 8 : Get date (hardware simulation)

Line 10-11 : Create a string. Note that the `DevString` object from `Tango::string_dup` is created on the heap

Line 13 : Create one instance of the `TimedAttrData` class with data and
date requesting the memory to be released.

Line 14 : Store this attribute history element in the history stack. The
element order will be the insertion order whatever the element date is.

Line 21 : Fill attribute polling buffer

It is not necessary to free the memory allocated at line 10. The
`fill_attr_polling_buffer` method will do it for you.

## Setting and tuning the polling in a Tango class

Even if the polling is normally set and tuned with external tools like
[Jive](inv:jive:std#index), it is possible to set it directly in the code of a Tango class.
A set of methods of the `DeviceImpl` class allows the user to
deal with polling. These methods are:

- `is_attribute_polled` and `is_command_polled` to check if one
  command/attribute is polled
- `get_attribute_poll_period` and `get_command_poll_period`
  to get polled object polling period
- `poll_attribute` and `poll_command` to poll command or
  attribute
- `stop_poll_attribute` and `stop_poll_command` to stop polling
  a command or an attribute

The following code snippet is just an example of how these methods could
be used:

```{code} cpp
:number-lines: 1

      void MyClass::read_attr(Tango::Attribute &attr)
      {
          ...

          std::string att_name{"SomeAttribute"};
          std::string another_att_name{"AnotherAttribute"};

          if(is_attribute_polled(att_name))
          {
              stop_poll_attribute(att_name);
          }
          else
          {
              poll_attribute(another_att_name, 500);
          }

          ....

      }
```